Electro­retino­graphy (ERG)

Advanced functional testing of the retina in dogs, cats, and other veterinary patients

Electroretinography (ERG) is a specialized, noninvasive test that measures the electrical response of the retina to light. It provides objective information about retinal function even when the retina cannot be visualized clearly because of cataract or other media opacity, and it can help distinguish retinal disease from optic nerve or central visual pathway disease.

At Animal Eye Consultants of Iowa, ERG is used as part of a comprehensive ophthalmic and neuro-ophthalmic evaluation and may be combined with chromatic pupil light reflex testing, optical coherence tomography (OCT), ocular ultrasound, and advanced imaging when clinically indicated.

What is electro­retino­graphy?

The retina converts light into electrical signals that ultimately travel through the optic nerve to the brain. ERG records the summed electrical activity generated by retinal cells after a controlled light stimulus. A small recording electrode is placed in contact with, or very close to, the cornea while reference and ground electrodes complete the recording circuit. The resulting waveform allows the ophthalmologist to evaluate whether retinal cells are responding normally and, in more advanced protocols, which retinal pathways are most affected.

The standard full-field ERG contains several recognizable components. The initial negative a-wave is generated predominantly by photoreceptor activity (rods and cones), while the subsequent positive b-wave reflects mainly ON-bipolar cell activity and other inner-retinal contributions. Slow components such as the c-wave relate in part to retinal pigment epithelium and photoreceptor-RPE interactions. The timing and amplitude of these signals provide complementary information about retinal function.

Basic components of the full-field ERG waveform and their retinal origins. PIII forms the leading edge of the negative a-wave; PII and PIII sum to generate the b-wave; PI and the slow PIII component produce the slow c-wave.

Why is ERG used in veterinary ophthalmology?

ERG answers a clinically important question: is the retina functioning? Because the test measures retinal electrical activity directly, it can be valuable when the patient cannot communicate visual symptoms and when the appearance of the eye alone does not explain the degree of visual impairment.

  • Preoperative retinal assessment before cataract surgery when the lens opacity prevents direct visualization of the retina.
  • Diagnosis of inherited retinal degeneration, including progressive retinal atrophy (PRA), and differentiation of rod-cone versus cone-rod dysfunction.
  • Confirmation of sudden acquired retinal degeneration syndrome (SARDS), in which a classic presentation may include sudden blindness with an initially near-normal fundus and a markedly reduced or nonrecordable full-field ERG.
  • Assessment of immune-mediated and cancer-associated retinopathies, which may produce selective or “suppressed” ERG abnormalities rather than a completely flat response.
  • Functional assessment in glaucoma and ocular hypertension, especially when inner-retinal or retinal ganglion-cell dysfunction is suspected.
  • Evaluation of unexplained visual loss when retinal disease must be distinguished from optic nerve, neurologic, or central visual pathway disease.
  • Monitoring retinal function over time in selected hereditary, inflammatory, toxic, ischemic, or treatment-related conditions.

Different ERG protocols provide different information

ERG protocolWhat it helps evaluate
Dark-adapted (scotopic) full-field ERGEmphasizes rod-dominated retinal function and mixed rod-cone responses. Particularly useful in hereditary retinal degeneration and diffuse retinal disease.
Light-adapted (photopic) ERGEmphasizes cone pathway function. Useful when cone dysfunction or cone-rod disease is suspected.
Flicker ERGRapid repetitive light stimulation isolates cone-dominated temporal responses and can reveal cone dysfunction that may be less obvious on a single-flash response.
Pattern ERG (pERG)Uses an alternating visual pattern rather than a simple flash and provides a functional measure strongly influenced by retinal ganglion cells. It can be useful in research and selected glaucoma/neuro-ophthalmic evaluations.
Multifocal ERG (mfERG)Maps localized retinal responses, particularly cone function in the central retina/area centralis, rather than averaging the electrical response of the entire retina.

Photopic flicker ERG (20 Hz). Repetitive stimulation is used to evaluate cone-dominated retinal responses.

Clinical examples

The following examples are drawn from our electroretinography teaching material and illustrate how ERG patterns can contribute to diagnosis and clinical decision-making. ERG findings are interpreted together with the complete ophthalmic examination, history, fundus appearance, OCT, chromatic pupil light reflex testing, and other diagnostic information.

1. SARDS: a “flat” or nonrecordable ERG

Sudden acquired retinal degeneration syndrome typically causes acute, profound visual loss. Early in the disease, the retina may appear relatively normal on ophthalmoscopy despite severe loss of photoreceptor function. A markedly reduced or nonrecordable full-field ERG therefore remains an important objective test supporting the diagnosis and helping distinguish SARDS from disorders located primarily in the optic nerve or brain.

Normal control responses (A) compared with a profoundly reduced, nonrecordable ERG in SARDS (B).

2. Immune-mediated retinitis and cancer-associated retinopathy

Not every immune-mediated retinal disorder produces a completely extinguished response. Some patients demonstrate selective reduction in rod, cone, flicker, pattern, or multifocal responses. This pattern can be clinically important in immune-mediated retinitis and cancer-associated retinopathy, where electrophysiology may reveal functional abnormalities before advanced structural degeneration is obvious.

Immune-mediated retinitis: “suppressed” ERG (C) compared with a normal control (A).

Cancer-associated retinopathy: “suppressed” ERG (D) compared with a normal control (A).

3. Glaucoma and retinal ganglion-cell function

Glaucoma is primarily an optic neuropathy, but acute or repeated elevations in intraocular pressure can affect multiple retinal layers. Conventional scotopic and photopic full-field responses may not always reflect early retinal ganglion-cell dysfunction. Pattern ERG is more directly influenced by retinal ganglion-cell activity and has been used in Dr. Grozdanić's research to characterize functional changes in canine glaucoma. In acute glaucomatous crises, ERG can also help document the severity and pattern of retinal ischemic injury, although visual prognosis must never be based on ERG alone.

Pattern ERG amplitude falls with elevated intraocular pressure (B) and improves after pressure reduction (C), compared with the fellow eye (A) and a healthy control (D).

Pattern ERG recording: an alternating checkerboard stimulus replaces a simple flash.

4. Pre-cataract surgery retinal screening

A dense cataract can prevent the ophthalmologist from seeing the retina. ERG is therefore commonly used before cataract surgery to determine whether the retina generates an appropriate electrical response. A satisfactory ERG does not guarantee postoperative vision, because optic nerve and brain function are not directly measured by full-field ERG, but it substantially improves the preoperative assessment of retinal function. Ocular ultrasound is often used alongside ERG to assess retinal attachment and posterior segment anatomy.

Pre-cataract screening in a 7-year-old Bichon: partial retinal detachment can reduce ERG amplitude, but some dogs retain near-normal full-field responses.

What happens during an ERG test?

  • The ophthalmologist selects the ERG protocol based on the clinical question. Some screening protocols can be performed with minimal restraint, while comprehensive testing may require sedation or general anesthesia to obtain stable, artifact-free recordings.
  • The pupils are typically dilated, and the cornea is protected with a coupling/viscoelastic solution before placement of the recording electrode.
  • Reference and ground electrodes are positioned, and a calibrated light source delivers flashes of defined intensity and timing.
  • For dark-adapted testing, the patient remains in darkness for a specified period so rod function can be assessed accurately. Light-adapted testing is then used to evaluate cone-dominated function when indicated.
  • The electrical waveforms are analyzed for amplitude, timing (implicit time), waveform shape, and reproducibility between eyes and relative to expected values for the protocol and patient.

Why technical quality matters

ERG measures very small electrical signals, so careful recording technique is essential. Electrical interference, loose or damaged electrodes, inadequate corneal contact, blinking, globe retraction, extraocular muscle activity, insufficient dark adaptation, or inappropriate filtering can distort the tracing. We pay close attention to recognizing 50/60-Hz electrical noise and biologic artifacts, because an artifact can mimic retinal dysfunction if the tracing is interpreted without adequate quality control.

How ERG fits with other advanced diagnostic tests

ERG is most powerful when combined with other functional and structural tests. Depending on the patient, Animal Eye Consultants of Iowa may combine ERG with chromatic pupil light reflex testing, optical coherence tomography (OCT), fundus photography, ocular ultrasound, gonioscopy, or CT/MRI. Together these tests help localize visual dysfunction to the photoreceptors, inner retina, retinal ganglion cells/optic nerve, or more central visual pathways and help guide treatment and prognosis.

Research and peer-reviewed work from Dr. Siniša D. Grozdanić

Dr. Siniša D. Grozdanić has co-authored peer-reviewed studies that used electroretinography to characterize retinal and optic-nerve function in canine retinal disease and glaucoma. Selected publications relevant to the clinical use of ERG include:

1.

Evaluation of retinal status using chromatic pupil light reflex activity in healthy and diseased canine eyes

Grozdanić SD, Matić M, Sakaguchi DS, Kardon RH. Investigative Ophthalmology & Visual Science. 2007;48(11):5178-5183. doi:10.1167/iovs.07-0249.

2.

Recovery of canine retina and optic nerve function after acute elevation of intraocular pressure: implications for canine glaucoma treatment

Grozdanić SD, Matić M, Betts DM, Sakaguchi DS, Kardon RH. Veterinary Ophthalmology. 2007;10(Suppl 1):101-107. doi:10.1111/j.1463-5224.2007.00584.x.

3.

Functional and structural changes in a canine model of hereditary primary angle-closure glaucoma

Grozdanić SD, Kecova H, Harper MM, Nilaweera W, Kuehn MH, Kardon RH. Investigative Ophthalmology & Visual Science. 2010;51(1):255-263. doi:10.1167/iovs.09-4081.

4.

Rapid diagnosis of retina and optic nerve abnormalities in canine patients with and without cataracts using chromatic pupil light reflex testing

Grozdanić SD, Kecova H, Lazić T. Veterinary Ophthalmology. 2013;16(5):329-340. doi:10.1111/vop.12003.

5.

Optical coherence tomography and molecular analysis of SARDS eyes suggests the immune-mediated nature of retinal damage

Grozdanić SD, Lazić T, Kecova H, Mohan K, Kuehn MH. Veterinary Ophthalmology. 2019;22(3):305-327. doi:10.1111/vop.12597.

6.

Presumed cancer-associated retinopathy mimicking SARDS in canines

Grozdanić SD, Lazić T, Kecova H, Mohan K, Adamus G, Kuehn MH. Veterinary Ophthalmology. 2021;24(2):125-155. doi:10.1111/vop.12853.

When should my pet be evaluated with ERG?

ERG may be recommended when a pet has unexplained vision loss, a suspected inherited or acquired retinal disease, a dense cataract that prevents direct retinal examination, or a condition in which objective measurement of retinal function will help guide treatment or prognosis. Your veterinary ophthalmologist will determine whether ERG alone or a combination of ERG, OCT, ultrasound, chromatic pupil testing, and advanced imaging is most appropriate.